Understanding ATEX requirements in explosive atmospheres

Explosive atmospheres can occur wherever flammable gases, vapours, mists or combustible dusts are present in sufficient concentration to ignite. Refineries, chemical plants, food production facilities, paint shops, fuel terminals, grain handling sites and wastewater treatment plants may all contain hazardous areas. A small ignition source can create a serious fire, flash fire or explosion when the right conditions exist.

ATEX provides a structured approach to controlling that risk. It brings together requirements for equipment used in potentially explosive atmospheres and duties placed on employers that operate sites where explosive atmospheres may form. In the UK, these requirements sit alongside risk assessment, hazardous area classification, maintenance controls and workforce competence.

Understanding ATEX standards for explosive atmospheres on site is therefore more than selecting equipment with the right label. It involves identifying where an explosive atmosphere could occur, assessing how often it may be present, controlling ignition sources and ensuring that people understand the limits of safe work.

What ATEX means in an industrial setting

ATEX comes from the French term “atmosphères explosibles”. In practical terms, it concerns an atmosphere containing a mixture of air and flammable substances that can ignite and propagate combustion. The substance may be a gas, vapour, mist or dust. The risk depends on factors such as concentration, temperature, ventilation, particle size and the presence of ignition energy.

Two related areas of regulation are commonly discussed. The product side covers equipment and protective systems intended for use in potentially explosive atmospheres. The workplace side covers how employers assess and control explosion risks. In Great Britain, the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016 apply to relevant products, while the Dangerous Substances and Explosive Atmospheres Regulations 2002, commonly called DSEAR, address workplace risks.

The legal arrangements differ in some respects across the UK. Great Britain and Northern Ireland have separate product conformity routes, and Northern Ireland continues to apply EU ATEX requirements in relevant circumstances. Organisations should check current government guidance when purchasing equipment, accepting certificates or placing products on the market. A competent person should also confirm which rules apply to the site, product and intended use.

How hazardous area zones are classified

Hazardous area classification describes the likelihood that an explosive atmosphere will be present. For gases, vapours and mists, Zone 0 is an area where an explosive atmosphere is present continuously, for long periods or frequently. Zone 1 is an area where it is likely to occur occasionally during normal operation. Zone 2 is an area where it is not likely to occur during normal operation, but could exist for a short time if it does.

Dust hazards use a parallel system. Zone 20 refers to an area where a combustible dust cloud is present continuously, for long periods or frequently. Zone 21 covers areas where a dust cloud is likely to occur occasionally in normal operation. Zone 22 covers areas where a dust cloud is not likely during normal operation but may exist briefly following an abnormal event.

Classification should be based on credible releases, ventilation, process conditions and the behaviour of the material. It is not enough to draw a fixed radius around a vessel or filling point without understanding the process. Leaking flanges, sampling points, bag emptying, dust extraction failures and cleaning activities may all influence the extent of a hazardous zone.

Selecting equipment for the classified area

ATEX equipment selection starts with the zone and the type of hazard. Equipment must be suitable for the atmosphere, the expected operating conditions and the possibility of an ignition source. A product that is appropriate for a gas hazard may be unsuitable for combustible dust, even where both areas have similar zone numbers.

Equipment markings contain important information. The marking can identify the equipment group, category, protection concept, gas or dust suitability and temperature limitations. Electrical equipment may use protection methods such as flameproof enclosures, increased safety, intrinsic safety or pressurisation. Non-electrical equipment, including mechanical pumps, couplings and fans, can also create ignition risks and must be assessed appropriately.

Temperature control is essential. For gas and vapour applications, temperature classes from T1 to T6 indicate the maximum surface temperature of the equipment. A lower permitted surface temperature provides greater protection for substances with lower ignition temperatures. Dust hazards require consideration of both cloud ignition and dust-layer ignition, since accumulated dust can insulate surfaces and raise their temperature.

Site consideration What it affects Practical check
Classified zone Required equipment category and protection level Confirm the product is approved for the specific zone
Gas, vapour, mist or dust Type of protection and certification Check whether the equipment marking includes G, D or the relevant approval
Ignition temperature Maximum permitted equipment surface temperature Compare the equipment temperature rating with the substance data
Ambient conditions Enclosure, seals, materials and certification limits Review temperature, moisture, corrosion and impact ratings
Installation method Integrity of the protection concept Follow manufacturer instructions and approved cable or gland requirements
Maintenance activity Whether protection remains effective over time Include inspections, cleaning, testing and repair in the maintenance plan

A compliant component can still become unsafe if it is installed incorrectly. Cable glands, junction boxes, earthing arrangements, seals, fasteners and entry systems all form part of the protection method. Modifications should be controlled through engineering review rather than treated as routine maintenance.

Managing ignition sources and process risks

A DSEAR assessment should examine how an explosive atmosphere could form and what could ignite it. Potential ignition sources include hot surfaces, flames, electrical arcs, static electricity, mechanical impact, friction, welding, portable equipment, vehicles, lightning and uncontrolled chemical reactions. Some ignition sources are obvious; others arise from routine tasks such as opening containers, transferring powder or using compressed air for cleaning.

The hierarchy of control should begin with prevention. Where possible, eliminate the dangerous substance, substitute it with a less hazardous material, reduce the quantity or operate at conditions that prevent an explosive mixture from forming. Effective ventilation, closed transfer systems, leak detection, inerting and dust extraction can reduce the likelihood of an explosive atmosphere.

Where the risk remains, equipment and procedural controls must work together. Bonding and earthing can control static, while permits, isolation, gas testing and controlled access can prevent ignition during non-routine work. Hot work near a classified area requires particularly careful planning because temporary activities may introduce a higher risk than normal operation.

Dust requires specific attention. Layers, deposits and accumulations can be disturbed into a cloud or ignite on heated surfaces. Cleaning arrangements should remove dust safely without spreading it or creating static. The assessment should cover hidden locations such as cable trays, roof spaces, ledges and the interiors of extraction systems.

Making inspections, maintenance and documents effective

ATEX compliance is not achieved when equipment is installed and certified. Protection can deteriorate through corrosion, loose covers, damaged seals, incorrect replacement parts, blocked vents, dust deposits or unauthorised modifications. Inspection and maintenance programmes should reflect the protection concept, the operating environment and the consequences of failure.

Records should show what was inspected, when it was inspected, who carried out the work and what defects were found. A finding such as a missing bolt on a flameproof enclosure or a damaged intrinsic safety barrier should be assessed promptly. Temporary repairs and deferred actions need clear controls so that a known defect does not become an accepted permanent condition.

Key documents commonly include the hazardous area classification drawings, explosion protection document, DSEAR assessment, equipment schedules, certificates, operating procedures, maintenance records and training evidence. These documents should agree with the plant as it exists. Changes to pipework, materials, ventilation, production rates or equipment may invalidate earlier assumptions and require reassessment.

Contractors need the same level of control as employees. Site induction should explain classified areas, access limits, permit requirements, emergency arrangements and the equipment they may use. Contractors should be able to demonstrate relevant competence, while the site operator remains responsible for coordinating work and managing interfaces between different teams.

Building competence through practical training

ATEX knowledge must be matched to a person’s role. An operator may need to recognise hazardous zones, follow transfer procedures and report defects. An electrician may need detailed knowledge of equipment certification, installation standards and inspection requirements. An engineer may need to evaluate design changes, while supervisors must be able to control permits, contractors and abnormal operations.

Training should cover the site’s actual hazards rather than relying only on generic theory. Participants benefit from seeing how zone boundaries relate to plant, where releases may occur and how equipment markings affect everyday decisions. Practical exercises can include interpreting hazardous area drawings, checking an equipment label, identifying ignition sources and reviewing a maintenance defect.

A realistic live-process-plant environment can make these lessons easier to apply. HCF CATCH supports industrial learning across process, energy, engineering, electrical, health and safety, industrial gas, and renewable energy disciplines. Its facilities provide a relevant setting for employers, apprentices and technical staff who need to connect ATEX principles with workplace behaviour.

Effective learning should be refreshed when processes change, after incidents or near misses, and when inspection findings reveal recurring weaknesses. Competence is demonstrated through safe performance, accurate decisions and appropriate escalation—not simply by attending a course.

Actions that strengthen ATEX control

  • Keep hazardous area drawings, equipment schedules and explosion protection documents aligned with the current plant.
  • Match every item of electrical and non-electrical equipment to the zone, substance, temperature limits and protection requirements.
  • Include dust deposits, temporary work, contractor activity and abnormal operations in explosion risk assessments.
  • Use planned inspections, defect tracking and controlled repairs to preserve the integrity of Ex equipment.
  • Provide role-specific training with practical exercises, site examples and clear evidence of competence.

Turn ATEX knowledge into site capability

A strong approach to ATEX begins with accurate classification and continues through design, procurement, installation, operation, maintenance and change management. Each stage depends on competent people making decisions that reflect the real process rather than relying on labels or assumptions.

HCF CATCH can help organisations develop that capability through practical industrial training, apprenticeships, safety qualifications and access to realistic process plant facilities. Employers can arrange training for teams, while individuals can build the technical understanding needed for safer work in hazardous areas.

Contact HCF CATCH to discuss ATEX-related training, industrial skills development or a suitable facility for your next technical learning event. Equip your people to identify explosive atmosphere risks, control ignition sources and protect the integrity of operations.